L-shaped retaining wall(type) - List of Manufacturers, Suppliers, Companies and Products

L-shaped retaining wall Product List

1~2 item / All 2 items

Displayed results

Precast L-shaped retaining wall 'ALW-TYPE1' <for road use>

Designed for a uniformly distributed load of 10 kN/m²! "50F to 250F" has obtained JIS II class certification.

We would like to introduce our precast L-shaped retaining wall 'ALW-TYPE1'. It is designed to support a uniformly distributed load of 10 kN/m², and it has obtained JIS II class certification for "50F to 250F". The design standard strength of the concrete is σck=36 N/mm², and the allowable shear stress is τca=0.26 N/mm². Please feel free to consult us when you need our services. 【Allowable Stress (Excerpt)】 ■Concrete - Design Standard Strength: σck=36 N/mm² - Allowable Bending Compressive Stress: σca=12 N/mm² ■Reinforcement - SD295A, SD345: σsa=160 N/mm² - SWM: σsa=140 N/mm² *For more details, please refer to the PDF materials or feel free to contact us.

  • Retaining wall
  • Concrete Retaining Wall

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Precast L-shaped retaining wall "ALWII-TYPEC"

The uniformly distributed load is 10 kN/m²! It complies with the standards of the Building Standards Act and the Land Development and Urban Planning Act for residential land development.

We would like to introduce our precast L-shaped retaining wall 'ALWII-TYPEC'. It is designed to withstand a uniformly distributed load of 10 kN/m². It complies with the standards of the Building Standards Act and the Land Development Act for residential land development. Please feel free to consult us when you need assistance. 【Soil Conditions and Others (Excerpt)】 ■ Lateral earth pressure coefficient of backfill soil: KA=0.35 (According to Article 7, Table 2 of the Enforcement Order of the Land Development Act) ■ Unit weight of backfill soil: γt=18.0 kN/m³ (According to Article 7, Table 2 of the Enforcement Order of the Land Development Act) ■ Unit weight of reinforced concrete: γc=24.0 kN/m³ *For more details, please refer to the PDF materials or feel free to contact us.

  • Retaining wall
  • Concrete Retaining Wall

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration